Post by
oldcompanyman on Nov 26, 2021 11:21am
For CGX drilling team
Gents,
I have no idea what you are doing right now, but just saying:
Your neighbors from across the border solved the losses below the 11-7/8" (i.e. your 11-3/4") with a cement squeeze using a stinger (if your nozzle sizes allow it, cement through the BHA, it will cost you less to pay for potential MWD damage than for a trip around). This should allow you to bring your losses to an acceptable level while keeping your upper zone with higher pore pressure in check and then run your 9-5/8".
Apologies for sticking my nose into your operations but XMas is around the corner.
Thanks for your attention,
And GLTA for the shareholders,
Comment by
oldcompanyman on Nov 26, 2021 11:26am
Could anyone with a stocktwits account put this information also on that board if possible? Just to increase the chances that someone at CGX reads it... Thanks,
Comment by
soulfire on Nov 26, 2021 11:34am
OCM you can email it to info@cgxenergy.com.... doubt they will read it though since they never reply. Additionally it can be sent to ir@frontera.com I will send it
Comment by
Dirksidetrack on Nov 26, 2021 11:46am
Good send it! I'm sure that Mr. Lacy would be happy to know that he could permanently stick a cesium radioactive source in the hole doing this insanity.
Comment by
Dirksidetrack on Nov 26, 2021 11:34am
Ok in 40 years in the oil patch I've never, ever seen cement pumped through a BHA. Live and learn.
Comment by
Dirksidetrack on Nov 26, 2021 11:41am
Ok in 40 years in the oil patch I've never, ever seen cement pumped through a BHA. Live and learn.
Comment by
oldcompanyman on Nov 26, 2021 3:37pm
HI SheDrills, I don't doubt their competencey but I just wanted them to know what the neighbors have done to go through these same zones on the very same layers. Crossing fingers for a good week-end for the rig team. GLTA,
Comment by
ljmorin on Nov 26, 2021 7:19pm
Oil is down all across the board Dickk, I mean Dirk. and about the % we are. Has nothing to do with two of problably the most experienced and respected posters on this board. Lay of of them most of us want their input certainly more than we want to hear yours.
Comment by
Dirksidetrack on Nov 26, 2021 7:31pm
Ok no problem there moron.
Comment by
Dirksidetrack on Nov 26, 2021 7:32pm
Ok no problem there moron.
Comment by
ljmorin on Nov 26, 2021 7:58pm
Hahaha, Aren't we witty. lol
Comment by
Dirksidetrack on Nov 26, 2021 8:11pm
Ok now we have it. No you cannot run a balanced plug through a BHA. Too many restrictions to calculate balance. At what depth did Apache run a balanced cement plug and why? Specify! You want to say critical stuff like that then specify! And no, I am not drunk. I rarely drink.