Join today and have your say! It’s FREE!

Become a member today, It's free!

We will not release or resell your information to third parties without your permission.
Please Try Again
{{ error }}
By providing my email, I consent to receiving investment related electronic messages from Stockhouse.

or

Sign In

Please Try Again
{{ error }}
Password Hint : {{passwordHint}}
Forgot Password?

or

Please Try Again {{ error }}

Send my password

SUCCESS
An email was sent with password retrieval instructions. Please go to the link in the email message to retrieve your password.

Become a member today, It's free!

We will not release or resell your information to third parties without your permission.
Quote  |  Bullboard  |  News  |  Opinion  |  Profile  |  Peers  |  Filings  |  Financials  |  Options  |  Price History  |  Ratios  |  Ownership  |  Insiders  |  Valuation

Thermal Energy International Inc V.TMG

Alternate Symbol(s):  TMGEF

Thermal Energy International Inc. provides energy efficiency and emissions reduction solutions to the fortune 500 and other multinational companies. It operates primarily in North America and Europe but also sells its products and services through representative agents throughout the rest of the world. It markets, sells, engineers, fabricates, constructs, installs and supports two technology lines, such as heat recovery solutions, including direct contact heat recovery solutions (FLU-ACE), indirect contact heat recovery solutions (HEATSPONGE and SIDEKICK), and condensate return system solutions (GEMTM steam traps). It is also developing several other technology lines, including low temperature biomass drying systems (DRY-REX). Its solutions can recover up to 80% of energy lost in typical boiler plant and steam system operations. It has two primary operational bases of operation, one in Ottawa, Canada and the other in Bristol, United Kingdom, covering Europe and the rest of the world.


TSXV:TMG - Post by User

Post by jonathon Dec 01, 2010 2:57pm
405 Views
Post# 17785135

Maintec March 29-31 2011

Maintec March 29-31 2011https://www.engineeringspecifier.com/Machinery-and-Plant-Equipment/Thermal-Energy-International-Unveils-A-Larger-Range-Of-Flu-ace-Systems-At-Maintec.asp

FLU-ACE systems

Thermal Energy International Unveils A Larger Range Of Flu-ace Systems At Maintec

News Release from: Thermal Energy International
30/11/2010

Thermal Energy International Inc. will be unveiling its modified range of FLU-ACE systems on stand D5 at Maintec 2011. Providing heat recovery and emission control in one package, FLU-ACE systems will be available in a broader range of sizes and are aimed at processing companies and institutions with both CHP waste heat boilers as well as traditional industrial boiler systems, wishing to take advantage of the substantial economic and environmental savings provided by recovering large amounts of lost heat and energy from the boiler exhaust.

Thermal Energy International Unveils A Larger Range Of Flu-ace Systems At MaintecMost natural gas or LP boilers and appliances are between 80 - 85% efficient, allowing 15 - 20% of the usable energy to escape up the chimney in the flue gases. By installing FLU-ACE equipment our customers have seen this upgraded to 90 - 95% efficiency and in addition dramatically reducing CO2 emissions. Large savings can also be made with CHP systems with the FLU-ACE providing even greater efficiencies of, in some cases, up to 100%.

FLU-ACE effectively converts an Industrial boiler into a condensing boiler, recovering waste heat to make hot water. During the boiler operation, water enters the top inlet of the economizer and is sprayed over the heat transfer media. Simultaneously, boiler flue gas is directed to the flue gas inlet, at the base of the economizer. Cold water, for example from the boiler feed water supply travels from the spray nozzle to counter-flow from the rising flue gas through the stainless steel transfer media. As the water droplets travel through the media, the hot flue gas rises to the top of the economizer directly contacting and preheating the water. Used either on its own or with an indirect economiser, water temperatures of up to 120’C can be achieved, whilst exhaust temperatures are reduced, often to around 25’C.

Conventional heat recovery technologies require dedicated equipment for each boiler exhaust. However a single FLU-ACE can handle a varying flow of flue gases emitted from multiple boiler exhausts. This results in a lower initial investment, cheaper operating costs and a higher potential return on investment. A full payback is often achieved in less than three years with continuing savings being maintained throughout the unit’s 20-year plus operating life.

The FLU-ACE unit’s internal structure ensures maximum condensing heat and mass transfer. It also enables an unobstructed flow of liquids and gases through the tower, providing continuous operation.

Thermal Energy International Inc will have a model of FLU-ACE displayed on their stand, which will enable visitors to Maintec to obtain a greater knowledge of the system and how it works.