New Found Intersects 9.12 g/t Au Over 8.20m & 42.6 g/t Au Over 11.75m Starting 9m From Surface & 55.1 g/t Au Over 5.10m at the Keats Main Zone
New Found Gold Corp. (“New Found” or the “Company”) (TSX-V: NFG, NYSE-A: NFGC) is pleased to announce assay results from 39 diamond drill holes designed to further delineate and expand the network of high-grade gold veins and associated structures at the Keats Zone. These holes were drilled as part of the Company’s ongoing 400,000m diamond drill program targeting +20km of prospective strike along the regional-scale Appleton (“AFZ”) and JBP fault zones at its 100% owned ~1500km2 Queensway project, accessible via the Trans-Canada Highway ~15km west of Gander, Newfoundland.
This press release features multimedia. View the full release here: https://www.businesswire.com/news/home/20220606005434/en/
Figure 1. Photo of mineralization from NFGC-22-593 at ~22m down hole depth. ^Note that these photos are not intended to be representative of gold mineralization in hole NFGC-22-593. (Photo: Business Wire)
Highlights:
Hole No. | From (m) | To (m) | Interval (m)1 | Au (g/t) | Zone |
NFGC-21-364A | 216.25 | 218.30 | 2.05 | 56.3 | Keats Main |
Including | 217.05 | 217.85 | 0.80 | 140.5 |
NFGC-21-388 | 123.00 | 128.65 | 5.65 | 9.0 | Keats Main |
Including | 126.95 | 128.30 | 1.35 | 31.5 |
NFGC-21-448 | 200.50 | 205.60 | 5.10 | 55.1 | Keats Main |
Including | 200.50 | 200.95 | 0.45 | 609.0 |
NFGC-21-466 | 169.70 | 172.05 | 2.35 | 10.9 | Keats Main |
NFGC-22-486 | 35.90 | 38.00 | 2.10 | 11.2 | 421 |
Including | 36.60 | 37.30 | 0.70 | 32.0 |
And | 371.40 | 373.60 | 2.20 | 10.1 | Keats Main |
Including | 371.75 | 372.45 | 0.70 | 30.0 |
NFGC-22-593 | 8.80 | 17.00 | 8.20 | 9.12 | Keats Main |
Including | 11.15 | 11.45 | 0.30 | 25.9 |
Including | 13.80 | 14.80 | 1.00 | 32.4 |
Including | 16.20 | 16.60 | 0.40 | 55.3 |
And | 20.50 | 32.25 | 11.75 | 42.6 |
Including | 20.50 | 21.00 | 0.50 | 111 |
Including | 21.90 | 22.20 | 0.30 | 338 |
Including | 22.90 | 23.30 | 0.40 | 733 |
Including | 29.60 | 30.10 | 0.50 | 25.8 |
Including | 31.35 | 32.25 | 0.90 | 21.8 |
And | 36.60 | 42.90 | 6.30 | 1.88 |
Table 1: Keats Drilling Highlights
1Note that the host structures are interpreted to be steeply dipping and true widths are generally estimated to be 60% to 95% of reported intervals. Infill veining in secondary structures with multiple orientations crosscutting the primary host structures are commonly observed in drill core which could result in additional uncertainty in true width. Composite intervals reported carry a minimum weighted average of 1 g/t Au diluted over a minimum core length of 2m with a maximum of 2m consecutive dilution. Included high-grade intercepts are reported as any consecutive interval with grades greater than 10 g/t Au. Grades have not been capped in the averaging and intervals are reported as drill thickness.
- A gap in the drilling at the north end of the Keats Main Zone in a structurally complex portion of the near surface extents of the Keats-Baseline Fault Zone (KBFZ) was recently tested with NFGC-22-593 which returned 9.12 g/t Au over 8.20m and 42.6 g/t Au over 11.75m, beginning at 8.8m down hole. This intercept extends the high-grade gold mineralization to surface in this area and indicates that there is a wide domain of high-grade gold veining immediately below the overburden; current modelling suggests that this thickened segment is approximately 125m in strike length and 35m wide (Figures 2, 3 and 4).
- 55.1 g/t Au over 5.10m in NFGC-21-448, 56.3 g/t Au over 2.05m in NFGC-21-364A, 9.0 g/t Au over 5.65m in NFGC-21-388, 10.9 g/t Au over 2.35m in NFGC-21-466 and 10.1 g/t Au over 2.20 in NFGC-22-486 are all intersections in the Keats Main Zone which to date has been defined over 845m down plunge and intersected at a vertical depth of 375m. The Keats Main Zone consists of a network of veins that is associated with the KBFZ which generally strikes N55°E and dips ~60° to the southeast (Figures 2, 3 and 5).
- Targeting the 421 Zone at the south end of Keats, NFGC-22-486 intersected 11.2 g/t over 2.10m at ~30m below surface. This high-grade gold mineralization is associated with an extensive moderately southwest dipping brittle fault zone that appears to play a role in localizing gold. The extents of this target area are not well constrained and this fault zone area and its projected intersections with the AFZ and KBFZ are high priorities for the current drilling (Figures 2 and 3).
Melissa Render, VP Exploration for New Found, stated: “Drilling continues to advance our understanding of the geometries and potential projections of the high-grade gold veins and faults that comprise the Keats. Our team is working tirelessly to keep the drills focused on expanding the zones discovered to date and concurrently building our understanding of the controls on the high-grade gold mineralization to allow continued optimization of targeting. Six drills are operating in and around Keats, with three working to tackle mineralization correlated to the main plunge and to depth, while an additional three drills are working at Keats North to follow-up on the recent near surface discoveries such as the 275 g/t Au over 2.15m in NFGC-22-538 (reported on May 4, 2022), 8.70 g/t Au over 6.75m in NFGC-22-533 (reported on May 4, 2022) and 43.9 g/t Au over 3.85m in NFGC-22-515 (reported on April 13, 2022) (Figure 3). Meanwhile, six more drills are systematically testing along the north segment of the AFZ. I would like to thank our exploration team for their ongoing dedication and hard work as we continue to advance this discovery.”
Discussion
Mineralization at the Queensway Project is hosted by a fold-thrust sequence of northeast-striking, steeply dipping turbiditic sedimentary rocks deposited and deformed during the closure of the Iapetus Ocean and subsequent continent-continent collision. During this prolonged period of continued shortening, at least two regional-deformation zones developed and include the Appleton (‘AFZ’) and JBP fault zones. The AFZ is interpreted to be a significant, deep-seated thrust fault, that strikes southwest across the full +100km length of the property and is likely the main conduit for the gold mineralizing fluids, much like the Cadillac-Larder Lake Fault Zone in the Abitibi.
As a result of progressive deformation, the brittle host stratigraphy developed an extensive network of gold-bearing fault zones enveloping the AFZ, the extents of which are not yet known. Higher-grades and widths of gold mineralization occur in areas where there was greater mineralizing fluid flow such as at structural intersections, at dilational openings within fault structures, and along lithological contacts where breakage occurs due to rheological differences in the compressional strength of contrasting sedimentary rock units.
Keats
Mineralization at Keats is associated with a significant east-northeast striking and moderately southeast dipping brittle fault zone, the Keats-Baseline Fault Zone (“KBFZ”) that developed adjacent to and trends at an oblique angle to the AFZ. Situated ~1.8km south of Lotto and 1.2km south of the Golden Joint discoveries, this fault forms an extensive damage zone that is discordant to the northeast striking and steeply dipping stratigraphy and controls the development of a complex network of high-grade gold vein arrays that are epizonal in character and exhibit breccia, stylolitic, and vuggy textures. The host rock units are comprised of an interbedded sequence of turbiditic shales and greywackes where lithological contrasts in part control domains of high-grade gold, however model advancements suggest the larger underlying control are dilational settings that experienced increased fluid flow that typically develop at structural intersections such as intersecting fault or vein segments. The KBFZ expresses itself as a topographic low and interpretation of this low has traced it over ~+2km strike length. At this stage, exploration has been largely focused within close proximity to the AFZ and has delineated a high-grade gold segment of the Keats-Baseline Fault over a strike length of ~660m, the high-grade southwest plunging dilational zone to ~845m while the deepest high-grade gold intercept to date is at a vertical depth of ~375m.
Drillhole Details
Hole No. | From (m) | To (m) | Interval (m)1 | Au (g/t) | Zone |
NFGC-21-364A | 216.25 | 218.30 | 2.05 | 56.3 | Keats Main |
Including | 217.05 | 217.85 | 0.80 | 140.5 |
NFGC-21-388 | 123.00 | 128.65 | 5.65 | 9.0 | Keats Main |
Including | 126.95 | 128.30 | 1.35 | 31.5 |
And | 135.75 | 139.10 | 3.35 | 4.2 |
Including | 138.60 | 139.10 | 0.50 | 21.5 |
NFGC-21-405 | No Significant Values | Keats Main |
NFGC-21-406 | 32.20 | 34.95 | 2.75 | 1.2 | Keats HW |
And | 48.30 | 51.00 | 2.70 | 2.1 |
And | 62.40 | 65.00 | 2.60 | 3.6 |
And | 209.00 | 211.15 | 2.15 | 1.8 |
And | 217.30 | 219.80 | 2.50 | 1.4 |
And | 280.00 | 282.00 | 2.00 | 1.2 | Keats Main |
NFGC-21-410B | 139.65 | 142.00 | 2.35 | 1.2 | Keats Main |
And | 174.20 | 176.50 | 2.30 | 1.8 |
NFGC-21-413A | 424.60 | 428.80 | 4.20 | 1.9 | Keats Main |
And2 | 463.05 | 467.55 | 4.50 | 28.2 |
Including2 | 463.05 | 466.00 | 2.95 | 41.0 |
NFGC-21-425 | 44.65 | 47.00 | 2.35 | 1.4 | Keats HW |
And | 107.35 | 109.45 | 2.10 | 1.3 | Keats Main |
And | 136.15 | 139.20 | 3.05 | 1.0 |
NFGC-21-426 | 255.10 | 257.55 | 2.45 | 1.5 | Keats FW |
NFGC-21-427 | 26.00 | 33.50 | 7.50 | 2.0 | 421 |
And | 37.50 | 39.80 | 2.30 | 1.1 |
And | 50.10 | 52.70 | 2.60 | 1.0 |
And | 60.85 | 63.00 | 2.15 | 1.1 |
And | 65.00 | 67.00 | 2.00 | 1.0 |
And | 131.00 | 133.00 | 2.00 | 1.9 |
And | 170.30 | 172.60 | 2.30 | 1.5 |
And | 175.00 | 177.00 | 2.00 | 1.3 |
And | 280.10 | 283.00 | 2.90 | 3.0 | Keats Main |
And | 285.10 | 288.00 | 2.90 | 3.0 |
NFGC-21-428 | 17.80 | 21.30 | 3.50 | 1.1 | Keats Main |
And | 57.55 | 59.55 | 2.00 | 1.3 |
And | 158.30 | 160.50 | 2.20 | 7.0 | Keats FW |
Including | 158.30 | 159.00 | 0.70 | 20.5 |
And | 173.90 | 176.00 | 2.10 | 1.2 |
NFGC-21-433 | 80.95 | 83.00 | 2.05 | 1.4 | Keats HW |
And | 90.00 | 93.00 | 3.00 | 7.0 |
Including | 92.00 | 93.00 | 1.00 | 19.5 |
And | 228.30 | 230.35 | 2.05 | 1.4 | Keats Main |
And | 237.70 | 240.00 | 2.30 | 2.5 |
NFGC-21-436 | 88.10 | 90.55 | 2.45 | 2.1 | Keats HW |
And | 140.70 | 142.70 | 2.00 | 12.9 | Keats Main |
Including | 141.00 | 141.65 | 0.65 | 39.6 |
NFGC-21-438 | 168.00 | 170.60 | 2.60 | 2.4 | Keats Main |
And | 204.35 | 206.85 | 2.50 | 9.0 |
Including | 204.35 | 205.10 | 0.75 | 28.5 |
And | 216.15 | 218.65 | 2.50 | 2.1 |
And | 246.85 | 249.00 | 2.15 | 2.2 |
NFGC-21-440 | 285.75 | 288.95 | 3.20 | 1.8 | Keats Main |
And | 362.15 | 365.55 | 3.40 | 2.0 |
NFGC-21-445 | No Significant Values | Keats Main |
NFGC-21-447 | 87.60 | 90.50 | 2.90 | 3.1 | Keats HW |
NFGC-21-448 | 184.70 | 187.00 | 2.30 | 1.3 | Keats Main |
And | 200.50 | 205.60 | 5.10 | 55.1 |
Including | 200.50 | 200.95 | 0.45 | 609.0 |
And | 284.00 | 286.35 | 2.35 | 4.0 |
NFGC-21-450 | No Significant Values | Keats Main |
NFGC-21-451 | 121.70 | 125.10 | 3.40 | 1.4 | Keats HW |
And | 130.00 | 132.15 | 2.15 | 1.3 |
And | 161.00 | 169.55 | 8.55 | 1.7 |
NFGC-21-454 | 209.55 | 213.25 | 3.70 | 2.7 | Keats Main |
NFGC-21-458 | 83.25 | 86.40 | 3.15 | 1.5 | Keats HW |
And | 120.55 | 122.75 | 2.20 | 5.6 |
Including | 121.10 | 121.65 | 0.55 | 21.5 |
And | 369.20 | 371.40 | 2.20 | 1.9 | Keats FW |
NFGC-21-460 | 166.40 | 168.75 | 2.35 | 1.1 | Keats Main |
And | 252.00 | 254.00 | 2.00 | 1.0 |
NFGC-21-466 | 169.70 | 172.05 | 2.35 | 10.9 | Keats FW |
NFGC-21-468 | 258.70 | 260.70 | 2.00 | 2.0 | Keats Main |
NFGC-22-472 | 40.00 | 42.00 | 2.00 | 1.9 | Keats HW |
NFGC-22-475 | No Significant Values | Keats Main |
NFGC-22-483 | 134.00 | 136.00 | 2.00 | 7.2 | Keats Main |
Including | 134.00 | 135.00 | 1.00 | 14.1 |
And | 138.60 | 140.90 | 2.30 | 3.9 |
Including | 138.60 | 139.30 | 0.70 | 10.9 |
And | 151.75 | 165.70 | 13.95 | 1.9 |
And | 177.30 | 180.00 | 2.70 | 1.1 |
NFGC-22-484 | 341.55 | 344.00 | 2.45 | 2.3 | Keats Main |
And | 425.65 | 428.10 | 2.45 | 1.7 |
And | 431.00 | 435.60 | 4.60 | 1.5 |
NFGC-22-486 | 35.90 | 38.00 | 2.10 | 11.2 | Keats HW |
Including | 36.60 | 37.30 | 0.70 | 32.0 |
And | 371.40 | 373.60 | 2.20 | 10.1 | Keats FW |
Including | 371.75 | 372.45 | 0.70 | 30.0 |
NFGC-22-487 | 134.00 | 136.40 | 2.40 | 1.1 | Keats HW |
And | 250.50 | 252.85 | 2.35 | 3.7 |
Including | 252.15 | 252.85 | 0.70 | 11.0 |
And | 517.50 | 519.50 | 2.00 | 1.2 | Keats Main |
NFGC-22-491 | 80.00 | 82.00 | 2.00 | 1.1 | Keats Main |
And2 | 92.00 | 95.00 | 3.00 | 79.8 |
Including2 | 92.45 | 94.35 | 1.90 | 124.6 |
And | 164.35 | 171.85 | 7.50 | 4.3 | Keats FW |
Including | 170.90 | 171.85 | 0.95 | 24.2 |
NFGC-22-492 | 92.15 | 94.25 | 2.10 | 3.8 | 421 |
And | 391.00 | 393.95 | 2.95 | 3.2 | Keats Main |
Including | 392.90 | 393.65 | 0.75 | 12.6 |
And | 398.15 | 400.35 | 2.20 | 5.1 |
Including | 398.45 | 399.05 | 0.60 | 14.3 |
NFGC-22-494 | No Significant Values | Keats East |
NFGC-22-511 | 77.00 | 79.00 | 2.00 | 1.29 | Keats HW |
And | 434.00 | 436.25 | 2.25 | 4.00 | Keats Main |
Including | 435.20 | 435.70 | 0.50 | 17.85 | Keats Main |
NFGC-22-514 | 149.00 | 151.05 | 2.05 | 2.06 | Keats FW |
NFGC-22-527B | 487.25 | 489.75 | 2.50 | 3.2 | Keats Main |
Including | 487.90 | 488.50 | 0.60 | 11.9 |
NFGC-22-537 | No Significant Values | Keats East |
NFGC-22-593 | 8.80 | 17.00 | 8.20 | 9.12 | Keats Main |
Including | 11.15 | 11.45 | 0.30 | 25.9 |
Including | 13.80 | 14.80 | 1.00 | 32.4 |
Including | 16.20 | 16.60 | 0.40 | 55.3 |
And | 20.50 | 32.25 | 11.75 | 42.59 |
Including | 20.50 | 21.00 | 0.50 | 111 |
Including | 21.90 | 22.20 | 0.30 | 338 |
Including | 22.90 | 23.30 | 0.40 | 733 |
Including | 29.60 | 30.10 | 0.50 | 25.8 |
Including | 31.35 | 32.25 | 0.90 | 21.8 |
And | 36.60 | 42.90 | 6.30 | 1.88 |
Table 2: Summary of composite results reported in this release for Keats.
1Note that the host structures are interpreted to be steeply dipping and true widths are generally estimated to be 60% to 95% of reported intervals. Infill veining in secondary structures with multiple orientations crosscutting the primary host structures are commonly observed in drill core which could result in additional uncertainty in true width. Composite intervals reported carry a minimum weighted average of 1 g/t Au diluted over a minimum core length of 2m with a maximum of 2m consecutive dilution. Included high-grade intercepts are reported as any consecutive interval with grades greater than 10 g/t Au. Grades have not been capped in the averaging and intervals are reported as drill thickness. 2 Previously reported interval.
Hole No. | Azimuth (°) | Dip (°) | Length (m) | UTM E | UTM N |
NFGC-21-364A | 120 | -80 | 299 | 657971 | 5427338 |
NFGC-21-388 | 120 | -71 | 242 | 657988 | 5427370 |
NFGC-21-405 | 300 | -45 | 308 | 658056 | 5427182 |
NFGC-21-406 | 325 | -56 | 396 | 657853 | 5427066 |
NFGC-21-410B | 297 | -46.5 | 257 | 658075 | 5427285 |
NFGC-21-413A | 296 | -57 | 515 | 658086 | 5427134 |
NFGC-21-425 | 299 | -45.5 | 269 | 658031 | 5427311 |
NFGC-21-426 | 120 | -50 | 335 | 657804 | 5427529 |
NFGC-21-427 | 325 | -56 | 431 | 657841 | 5427083 |
NFGC-21-428 | 299 | -42.5 | 238 | 657976 | 5427343 |
NFGC-21-433 | 299 | -45.5 | 314 | 658009 | 5427209 |
NFGC-21-436 | 300 | -45 | 350 | 657970 | 5427232 |
NFGC-21-438 | 299 | -45.5 | 350 | 658094 | 5427246 |
NFGC-21-440 | 119 | -47 | 425 | 657748 | 5427446 |
NFGC-21-445 | 298 | -57 | 344 | 658280 | 5427369 |
NFGC-21-447 | 300 | -45 | 371 | 657999 | 5427158 |
NFGC-21-448 | 299 | -45.5 | 329 | 658074 | 5427257 |
NFGC-21-450 | 298 | -57 | 371 | 658418 | 5427406 |
NFGC-21-451 | 325 | -56 | 434 | 657810 | 5427057 |
NFGC-21-454 | 299 | -45.5 | 401 | 657989 | 5427163 |
NFGC-21-458 | 325 | -56 | 455 | 657814 | 5427087 |
NFGC-21-460 | 299 | -45.5 | 356 | 657956 | 5427182 |
NFGC-21-466 | 300 | -45 | 338 | 657943 | 5427161 |
NFGC-21-468 | 300 | -45 | 527 | 657997 | 5427129 |
NFGC-22-472 | 325 | -56 | 494 | 657836 | 5427050 |
NFGC-22-475 | 298 | -57 | 527 | 658249 | 5427215 |
NFGC-22-480 | 120 | -45 | 425 | 657864 | 5427742 |
NFGC-22-483 | 299 | -45.5 | 235 | 658214 | 5427379 |
NFGC-22-484 | 240 | -45 | 470 | 658030 | 5427310 |
NFGC-22-486 | 30 | -65 | 419 | 657815 | 5427088 |
NFGC-22-487 | 245 | -42 | 574 | 657996 | 5427136 |
NFGC-22-491 | 299 | -45.5 | 206 | 658300 | 5427503 |
NFGC-22-492 | 23 | -64 | 440 | 657811 | 5427057 |
NFGC-22-494 | 299 | -45.5 | 266 | 658907 | 5427777 |
NFGC-22-511 | 22 | -60 | 470 | 657778 | 5427033 |
NFGC-22-514 | 299 | -45.5 | 205 | 658295 | 5427493 |
NFGC-22-527B | 294 | -47.5 | 731 | 657945 | 5426843 |
NFGC-22-537 | 299 | -45.5 | 212 | 658867 | 5427859 |
NFGC-22-593 | 300 | -45 | 119 | 658214 | 5427523 |
Table 3: Details of drill holes reported in this release.
Queensway 400,000m Drill Program Update
Approximately 48% of the planned 400,000m program at Queensway has been drilled to date with ~21,700m of the core with pending assay results. Twelve core rigs are currently operating and New Found is targeting an increase in the drill count to 14 rigs.
Sampling, Sub-sampling, Laboratory and Discussion
True widths of the intercepts reported in this press release have yet to be determined but are estimated to be 60% to 95% of reported core lengths. Infill veining in secondary structures with multiple orientations crosscutting the primary host structures are commonly observed in drill core which could result in additional variability in true width. Assays are uncut, and composite intervals are calculated using a minimum weighted average of 1 g/t Au diluted over a minimum core length of 2m with a maximum of 2m consecutive dilution. Included high-grade intercepts are reported as any consecutive interval with grades greater than 10 g/t Au.
All drilling recovers HQ core. Drill core is spit in half using a diamond saw or a hydraulic splitter for rare intersections with incompetent core.
A professional geologist examines the drill core and marks out the intervals to be sampled and the cutting line. Sample lengths are mostly 1.0 meter and adjusted to respect lithological and/or mineralogical contacts and isolate narrow (<1.0m) veins or other structures that may yield higher grades. Once all sample intervals have been chosen, photos of the wet and dry core are taken for future reference.
Technicians saw the core along the defined cut-line. One-half of the core is kept as a witness sample and the other half is submitted for crushing, pulverizing, and assaying. Individual sample bags are sealed and placed into shipping pails and/or nylon shipping bags, sealed and marked with the contents.
Drill core samples are shipped to either ALS Canada Ltd. (ALS) for sample preparation in Sudbury, Ontario or Eastern Analytical Ltd. (EAL) in Springdale, Newfoundland. Both laboratories are ISO-17025 accredited. All assay laboratories operate under a commercial contract with New Found.
At both laboratories the entire sample is crushed to ~80% passing 2 mm. At ALS, a 3,000-g split is pulverized. “Routine” samples do not have visible gold (VG) identified and are not within a mineralized zone. Routine samples are assayed for gold by 50-g fire assay with an inductively-couple plasma spectrometry (ICP) finish. If the initial 50-g fire assay gold result is over 1 g/t, the remainder of the 3,000-g split is screened at 106 microns for screened metallics assay. For the screened metallics assay, the entire coarse fraction (sized greater than 106 microns) is fire assayed and two splits of the fine fraction (sized less than 106 microns) are fire assayed. The three assays are combined on a weight-averaged basis.
Samples that have VG identified or fall within a mineralized interval are automatically submitted for screened metallic assay for gold.
EAL receives routine samples. A 250-g split of the crushed material is pulverized, and a 30-g subsample is fire assayed for gold with an atomic absorption spectrometry (AAS) finish.
All sample pulps are also analyzed for a multi-element ICP package (ALS method code ICP61).
Drill program design, Quality Assurance/Quality Control and interpretation of results is performed by qualified persons employing a rigorous Quality Assurance/Quality Control program consistent with industry best practices. Standards and blanks account for a minimum of 10% of the samples in addition to the laboratories internal quality assurance programs.
Quality Control data are evaluated on receipt from the laboratories for failures. Appropriate action is taken if assay results for standards and blanks fall outside allowed tolerances. All results stated have passed New Found’s quality control protocols.
New Found’s quality control program also includes submission of the second half of the core for ~2% of the drilled intervals. In addition, ~3% of sample pulps for mineralized samples are submitted for re-analysis to a second ISO-accredited laboratory for check assays.
The company does not recognize any factors of drilling, sampling or recovery that could materially affect the accuracy or reliability of the assay data disclosed.
The assay data disclosed in this news release have been verified by the Company’s Qualified Person against the original assay certificates.
The Company notes that it has not completed any economic evaluations of its Queensway Project and that the Queensway Project does not have any resources or reserves.