Post by
geodude13 on Feb 15, 2011 10:55pm
Reference to a choke on the Parex website
A little more detailed information on the parex website and a reference to a choke. Hopefully the additional detail can shed more light on the reservoir. Still hoping a reservoir engineer weighs in on the interpretation?
The Snowcap-1 well tested the primary Herrera zone (4,590-4,605 feet) in a multi-point test over the perforated interval at 4,597-4,603 feet. The final four day gross rate averaged 580 bopd of 35 API oil and 5.4 mmscfd with wellhead pressure of 600 psi on a 48/64th inch choke under natural flow. The final six hours of flow on that choke averaged 500 bopd and 4.7 mmscfd at 580 psi. During the initial seven hour clean-up period, the zone flowed at rates averaging 1,166 bopd and 1.6 mmscfd at 1,200 psi. The well is currently shut-in to record down-hole pressure build-up for analysis of the test.
Regards