VANCOUVER, BC, Jan. 20, 2022 /CNW/ - First Energy Metals Ltd. (CNSX: FE) ("First Energy" or the "Company) is pleased to announce results of drill hole LC21-18 at its Augustus Lithium Property in Quebec, Canada. The drill hole intersected several spodumene bearing lithium pegmatite intercepts from 58.2 metres (m) to 160 m drilled depth; of which the most promising intercept grading 1.56 percent (%) lithium oxide (Li2O) over 6 m at 114 m drilled depth, and a second 19 m wide intercept grading 0.48% Li2O at 141 m drilled depth. There are anomalous values of other rare metals such as beryllium (Be), cesium (Cs), niobium (Nb), rubidium (Rb) and tantalum (Ta).
Highlights (see Table 1 for details)
- 7.5 m wide spodumene pegmatite zone at 58.2 m with lithium grades in the range of 0.15% to 0.59% Li2O.
- 1.9 m wide spodumene pegmatite zone at 104.4 m with average lithium grade of 0.55% Li2O.
- 6 m wide spodumene pegmatite zone at 114 m with average grade of lithium 1.56% Li2O, 218.83 parts per million (ppm) Be, 56.75 ppm Cs, 77.78 ppm Nb, 1,297.83 ppm Rb, and 88.98 ppm Ta.
- 19 m wide spodumene pegmatite zone at 141 m with average grade of lithium 0.48% Li2O, 152.84 ppm Be, 53.42 ppm Cs, 93.57 ppm Nb, 1,854.16 ppm Rb, and 68.75 ppm Ta.
Drill hole LC-21-18was drilled during Phase 1 in 2021 at Augustus Prospect, UTM location: 287095.86E, 5367778.51N (NAD 1983 UTM Zone 18N), Azimuth 44.65 degrees (TN), Dip -64 degrees with a total drilled depth of 249 m. All intersections reported are based on drilled width and have not been converted to the true width. The drill core was logged and sampled at the core shack using a rock saw. For quality control and quality assurance (QA/QC), field duplicates, standards and blanks were inserted at industry standard intervals. The samples were bagged and tagged using best practices and were delivered to Activation Laboratories ("ACTLABS"), Ancaster, Ontario for sample preparation and analyses using laboratories code Ultratrace 7 and sodium peroxide fusion (Na2O2). ACTLABS is an independent commercial, accredited ISO Certified Laboratory.
Afzaal Pirzada, P.Geo., Geological Consultant of the Company, and a "Qualified Person" for the purposes of National Instrument 43-101 - Standards of Disclosure for Mineral Projects, has reviewed and approved the scientific and technical information contained in this news release.
ON BEHALF OF THE BOARD OF
FIRST ENERGY METALS LTD.
"Gurminder Sangha"
Gurminder Sangha
CEO & Director
Neither the Canadian Securities Exchange (CSE) nor its Regulation Services Provider accepts responsibility for the adequacy or accuracy of this news release and has neither approved nor disapproved the contents of this news release.
Forward-looking Information
Except for the statements of historical fact, this news release contains "forward-looking information" within the meaning of the applicable Canadian securities legislation that is based on expectations, estimates and projections as at the date of this news release. "Forward-looking information" in this news release includes information about the Company's information concerning the intentions, plans and future actions of the parties to the transactions described herein and the terms thereon.
The forward-looking information in this news release reflects the current expectations, assumptions and/or beliefs of the Company based on information currently available to the Company. In connection with the forward-looking information contained in this news release, the Company has made assumptions about the Company's ability to obtain required approvals. The Company has also assumed that no significant events occur outside of the Company's normal course of business. Although the Company believes that the assumptions inherent in the forward-looking information are reasonable, forward-looking information is not a guarantee of future performance and accordingly undue reliance should not be put on such information due to the inherent uncertainty therein.
Table 1: Drill Hole LC21-18 Assay Highlights
Analyte Symbol
|
Depth From
|
Depth To
|
Total Thickness
|
Li
|
Li2O
|
Be
|
Cs
|
Nb
|
Rb
|
Ta
|
Unit Symbol
|
m
|
m
|
m
|
ppm
|
%
|
ppm
|
ppm
|
ppm
|
ppm
|
ppm
|
Detection Limit
|
|
|
|
3
|
|
3
|
0.1
|
2.4
|
0.4
|
0.2
|
Analysis Method
|
|
|
|
FUS-MS-Na2O2
|
201896
|
58.2
|
60
|
1.8
|
1910
|
0.41
|
101
|
37.5
|
29.7
|
274
|
64.9
|
201897
|
60
|
60.5
|
0.5
|
1640
|
0.35
|
48
|
274
|
67.3
|
2400
|
497
|
201898
|
64
|
65
|
1
|
2760
|
0.59
|
105
|
103
|
41.8
|
520
|
113
|
201899
|
65
|
65.7
|
0.7
|
712
|
0.15
|
58
|
6.3
|
54.6
|
58.1
|
105
|
201901
|
70.8
|
72
|
1.2
|
680
|
0.15
|
31
|
133
|
41
|
950
|
106
|
201902
|
76.7
|
78
|
1.3
|
1190
|
0.26
|
455
|
51.6
|
53.5
|
193
|
112
|
201903
|
88.4
|
89.2
|
0.8
|
317
|
0.07
|
229
|
139
|
81.1
|
373
|
120
|
201904
|
104.4
|
105
|
0.6
|
3770
|
0.81
|
194
|
40.5
|
78.8
|
338
|
150
|
201905
|
105
|
105.5
|
0.5
|
2660
|
0.57
|
192
|
28.7
|
82.8
|
247
|
180
|
201906
|
105.5
|
106.3
|
0.8
|
1270
|
0.27
|
176
|
35
|
87
|
312
|
180
|
201907
|
113.5
|
114
|
0.5
|
4850
|
1.04
|
157
|
202
|
72.9
|
1140
|
101
|
First Li Intercept
|
|
|
0
|
|
|
|
|
|
|
|
201908
|
114
|
115
|
1
|
9340
|
2.01
|
305
|
41.3
|
84.6
|
207
|
60.9
|
201909
|
115
|
116
|
1
|
6380
|
1.37
|
238
|
53.1
|
76
|
1450
|
104
|
201911
|
116
|
117
|
1
|
7990
|
1.72
|
188
|
83.7
|
72.8
|
1950
|
141
|
201912
|
117
|
118
|
1
|
6320
|
1.36
|
212
|
50.3
|
84.5
|
1290
|
92.1
|
201913
|
118
|
119
|
1
|
6070
|
1.31
|
175
|
58.3
|
76.8
|
1460
|
69.3
|
201914
|
119
|
120
|
1
|
7340
|
1.58
|
195
|
53.8
|
72
|
1430
|
66.6
|
Total / Average
|
114
|
120
|
6
|
7240
|
1.56
|
218.83
|
56.75
|
77.78
|
1297.83
|
88.98
|
201915
|
120
|
120.6
|
0.6
|
2270
|
0.49
|
147
|
52.5
|
83.8
|
1450
|
70.1
|
201916
|
140
|
141
|
1
|
217
|
0.05
|
248
|
38
|
27.8
|
433
|
24.2
|
Second Li Intercept
|
|
|
|
|
|
|
|
|
|
|
201917
|
141
|
142
|
1
|
1330
|
0.29
|
266
|
36.3
|
102.2
|
469
|
102
|
201918
|
142
|
143
|
1
|
3410
|
0.73
|
191
|
42.3
|
82.6
|
1110
|
62.4
|
201919
|
143
|
144
|
1
|
2700
|
0.58
|
186
|
54.8
|
86.3
|
1870
|
65.7
|
201921
|
144
|
145
|
1
|
2330
|
0.50
|
98
|
71.3
|
116.1
|
2770
|
66.7
|
201922
|
145
|
146
|
1
|
2970
|
0.64
|
80
|
70.1
|
93.4
|
2630
|
54
|
201923
|
146
|
147
|
1
|
674
|
0.14
|
133
|
40.9
|
103
|
1300
|
57.3
|
201924
|
147
|
148
|
1
|
1760
|
0.38
|
223
|
46.3
|
109.5
|
1440
|
85.7
|
201926
|
148
|
149
|
1
|
2760
|
0.59
|
242
|
63.6
|
106.3
|
1940
|
73.5
|
201927
|
149
|
150
|
1
|
3960
|
0.85
|
181
|
64.3
|
128.9
|
1500
|
118
|
201928
|
150
|
151
|
1
|
2570
|
0.55
|
105
|
66.5
|
100.7
|
2450
|
60.1
|
201929
|
151
|
152
|
1
|
3060
|
0.66
|
97
|
72.5
|
74.8
|
2740
|
78.5
|
201931
|
152
|
153
|
1
|
2760
|
0.59
|
111
|
41.3
|
84.8
|
1280
|
48.1
|
201932
|
153
|
154
|
1
|
659
|
0.14
|
131
|
44.7
|
94
|
1600
|
59.2
|
201933
|
154
|
155
|
1
|
1480
|
0.32
|
145
|
51
|
78.6
|
2250
|
46.1
|
201934
|
155
|
156
|
1
|
455
|
0.10
|
128
|
36.4
|
110.5
|
1500
|
96.6
|
201935
|
156
|
157
|
1
|
411
|
0.09
|
106
|
35.2
|
67.9
|
1440
|
50.7
|
201936
|
157
|
158
|
1
|
1980
|
0.43
|
150
|
65.4
|
75.9
|
2940
|
47.8
|
201937
|
158
|
159
|
1
|
6350
|
1.37
|
205
|
61.1
|
80.9
|
1920
|
70.2
|
201938
|
159
|
160
|
1
|
594
|
0.13
|
126
|
50.9
|
81.5
|
2080
|
63.6
|
Total / Average
|
141.00
|
160.00
|
19.00
|
2,221.74
|
0.48
|
152.84
|
53.42
|
93.57
|
1,854.16
|
68.75
|
201939
|
160
|
161
|
1
|
140
|
0.03
|
115
|
54.5
|
76.9
|
2750
|
63.1
|
201941
|
161
|
161.5
|
0.5
|
183
|
0.04
|
220
|
48.8
|
66.6
|
1610
|
41.2
|
Note: A standard conversion factor of 2.15 was used to report Li to Li2O values
All intersections reported are based on drilled width and have not been converted to the true width.
SOURCE First Energy Metals Limited
View original content: http://www.newswire.ca/en/releases/archive/January2022/20/c8576.html